Permanent antistatic agent

Mechanism of permanent antistatic agent

Generate a conductive network during compounding/processing then discharge through the pathway.

Types & features of antistatic agents

TypeMigratory additivesPermanent antistaticconductive carbon black/nanotube
Surface resistivity levelAntidust to ESDAntidust to ESDConductive
Humidity DependentYesNoNo
Typical dosage0.2-2%7-20%3-10%
Resistance level Range109-10 12108-10 14104-105
Advantages• Low dosage• No bleed-out, No polluting

• Perform immediately & long lasting

• Best performance

• Lower cost compared with permanent antistatic

Drawback• Bleed-out

• Performance loss by washing

• Short term effective

• Higher dosage & costs• Negative impact on mechanical,

• Black color only

baoxu permanent antistatic agent products

ItemBX ATA P100BX ATA P200
FormSolid, without carrierSolid, without carrier
ColorWhite to Light yellow colorWhite to Light yellow color
Melting Point ℃>90>100
Surface resistivity (25 °C, 50%R.H.)

[ohms/sq.]

107106
ApplicationPolyolefin, PP, PE, TPO, HDPEEngineering Plastics, PA, PET/PBT, POM,

ABS, ASA, HIPS, PC/ABS alloy.

Features of permanent antistatic additive

  • No migrating side effects.
  • for both anti-dust and static dissipative applications.
  • maintain mechanical properties of the polymer.
  • easy processed by extrusion or injection process.
  • odorless
  • light color.
  • halogen-free.
  • long-lasting performance

Typical application data

BX ATA P100 performance in PP

PolypropylenePA100surface resistivity [Ω/sq.]
9551013-1014
90101012-1013
85151012
80201011

Processing condition: Extrusion @230℃, Injection@230℃

BX ATA P200 performance in PC/ABS

PC/ABS=7/3PA200surface resistivity [Ω/sq.]
9551013-1014
90101011
85151010
8020109

Processing condition: Extrusion @250-260℃, Injection@250-260℃

Dosage

7-15% based on polymer and applications.

Handling

  • Baoxu permanent antistatic agent product is very hygroscopic substance that is dried before shipping. Store under cool and dry conditions. After opening, use immediately.
  • Keep closed when not in use. In case of that, this product absorbs moisture, drying at 70-80 ºC for 3h under a vacuum is required before use.